very helpful. Answered our questions. Completed the work efficiently.
Amador’s customer service is on par with his technical skills. Hydes comes through again with exceptional service and competitive pricing. Highly recommend
Hydes is my go to for any heating air conditioning or lighting needs. I trust them to do the job right without hidden fees or up costs. All their service technicians are fantastic
Response from Hydes Air Conditioning:
Thanks so much. We really appreciate you putting your trust in us. Thanks for the wonderful review as well Nancy.
Taylor was the perfect tech. Clearly knowledgeable and answered all our questions. And, he want through the state of both our units.
Miguel once again did everything efficiently and timely!
Amador is very professional, knowledgeable, and polite. He explained to me everything in detail and vas very respectful including of my carpet. Lol He did an excellent job!!!
Thor is our favorite tech- he’s happy professional and personable Very nice person
Performed a cooling maintenance on a 2020 American Standard 5 ton condenser. Replaced a 24x24 filter located inside closet/laundry room. Cycled cooling system, checked refrigerant levels, verified voltages and system amperages. Found capacitor still within range. Also found start up current within specifications. Cleared condensation line and washed condenser coil. Cooling system is operational at this time.
Cooling service and safety check on 2023 equipment. Verified sequence of operations are working properly according to manufacturer specifications. Replaced filters, cleared drain lines.
Upon arrival, found blank thermostat, and no present at thermostat. check furnace and found 5 flash error code/ open fuse. Check the obvious for shorted wires, touching wires anything that can be causing fuse to pop. With further investigation found bad contactor, and thermostat. Replaced contactor, thermostat and ohmed wires to make sure all wires were good. Installed new contactor and ecobee thermostat tested equipment and verified second stage cooling system is now operating and cooling. Set thermostat to mobile app, had client call ecobee for assistance if this doesn’t work then I might need to come back to further assist .
Executed a cooling maintenance on two split systems (technician notes). Washed down condenser coils, replaced and washed filters, cleared condensate drain line and cleaned circuit cabinet with CO2 tank. Minor alerts on CDA. Erased alert history. Adjusted installer set up menu. Cycle system in cooling. Temperature and pressure documented in photos. Temperature split 23°. Estimate sent for surge protection options. Both systems are cooling the home at the time of maintenance.
Did a visual check seen oil at the coil we will be replacing coil under warranty, for office to schedule
Found system is cooling properly at this time, although thermostat location isn’t favorable causing inconsistencies in temperature throughout 5e different bedrooms. Went over options with client. Sending remainin estimates via email.
Performed annual cooling maintenance on a 2016 American Standard Silver 5 ton unit and a 2018 American Standard Silver 3 ton unit. FAUs located in garage and outdoor closet. Client had replaced customer supplied media filters prior to arrival. Followed sequence of operations and checked voltage, amperage, capacitor, hard start kit, temperature split, Freon levels, cleated condensation lines from FAUs, and rinsed condenser coils. Everything checked out in range. Both Honeywell 6000 thermostats checked out operational. Both systems are working to manufacture specifications in cooling at this time of service.
Performed a cooling maintenance on two condenser units, check, refrigerant levels, as well as all electrical components. At this time all is within manufacturer specifications and all is within range and both systems are cooling the house properly at this time both unit reached temperature of 70° . finish maintenance by blowing out condensation lines and washing out washable filters both located by FAU will send home owners estimate for a hard start kit for XL condenser unit.
Performed a cooling maintenance on a 2019 lennex condenser unit. Checked sequence of operations by checking refrigerant levels as well as all electrical components. As shown in pictures, at this time all is within manufacture specifications and system is cooling properly at this time. Finished maintenance by blowing out condensation line and changing out filter both located by FAU ad washed down outdoor unit.
quote to pump down system remove outdoor unit and Re-anchor L bracket evacuate and re charge system
Upon arrival system was not cooling after Diagnostic found that it was low on Freon add to 10 pounds of 410 a system is up and cooling at this time we will be doing a leak check on Wednesday
Performed annual maintenance in cooling on a 3 ton r 22 , followed Sequence of operation Changed filter checked amps voltage capacitor compressor savor working at range cleared condensation line rinsed condenser down, unit is working to manufacture specification in cooling at this time of visit
Performed monthly maintenance in cooling on a 2022 American standard, followed sequence of operation Changed filter checked amps voltage temperature split CDA working at range cleared condensation line rinsed condenser down, unit is working to manufacture specification in cooling at this time of visit
Performed annual maintenance in cooling on 2 York r 22 , followed Sequence of operation Changed filters checked amps voltage capacitors working at range checked pressures living room area last 4 0817 added 4 pounds 421a balance pressures, cleared condensation lines rinsed condensers down units are working to manufacture specification in cooling at this time of visit due recommend replacement due that unit has leak and r 22